Quality That Lasts.

T961Y Feed Water Control Valve, Control Signal 0~10 or 4~20mA
Contact:Sales Department
Tel:+86-21 5620 6641
Mobile:+86-13127946805
Email:info@shinjovalve.com
Tags:

T961Y Feed Water Control Valve, Control Signal 0~10 or 4~20mA

BRIEF INTRODUCTION

 The T961Y feed water control valve is also widely used independently for installation on the feeding water pipeline of boiler and the bypass of the cooling water of the high pressure heater to adjust the flow rate. The valve is derived by pneumatic actuator with positioner, and electrical actuator is also available. 

 STRUCTURE FEATURES

 

T961Y Feed Water Control Valve

No

Part

Material

1

Body                  

A105

2

Bonnet

A105                                       

3

Stem

SS304 / 20Cr13            

4

Disc

SS304 / 20Cr13                    

5

Seat

SS304 /  20Cr13                   

6

Packing

Flexible Graphite

 1. The valve is mainly made of body, seat, sleeve, support, stem and bonnet and so on, apply with the electric actuator and pneumatic actuator

2. As for this series control valves, the seat and disc are designed out with many different structure types, it can meet many different throttle way and its flow characteristic are two types of linear and equal-percentage.
3. The valve is Z shape structure, multi-level throttle, and high adjusting accuracy, can adjust the cooling water for many different differential pressure and flow types condition.
4. Every level of throttle part was made of reasonable linear type, which can prevent the cavitation and noise, and keep the adjusting steadily.
5. The sealing ring between the seat applies with the flexible graphite with good compressibility and sealing performance, when the valve is closed, it hardly has the leakage.
 

INSTALLATION

1. The valve must be installed on the pipeline vertically, connected with flange.
2. The flow direction on the valve body shall same to the installation direction.
3. In installation, the opening and closing position of the electric actuator shall same to the valve.
4. When clean the pipeline, some necessary measures shall be took in order to prevent the valve from sticking because of something left between the disc and seat, which may reduce the working life.
 CONFIRMATION BEFORE ORDER

① Type (Including the actuator type, connect type, and material of the body and so on).
② Nominal Pressure PN (MPa).
③ Nominal Diameter DN (mm).
④ Working Pressure (MPa).
⑤ Pressure differential of Water: Inlet pressure (MPa) and outlet pressure (MPa).
⑥ Water Temperature (℃).
⑦ Cv value or the maximal flow rate (t/h).
⑧ Other technical requirement.
If the electric actuator is applied, the controlling signal shall be noted (0~10 or 4~20mA), if the pneumatic actuator is applied, bellow information shall be noted:
① If hand wheel is needed;
② Air filter pressure reducer;
③ Positioner, if it is the electro pneumatic valve positioner, please note the electric signal (0~10 or 4~20mA);
④ Air supply pressure;
⑤ Air-closing or air-opening.

 


About Us

Shinjo Company is a high tech enterprise specialized in producing various industrial valves. Shinjo strive on providing full package of industrial valve solution to client, focus on industrial valve manufacture, development, sales and services.

Contact Us
Tel: +86-21 5620 6641
Fax: +86-21 6915 6667
Mobile: +86-13127946805(WhatsApp)
Skype: maxchi2013
Fllow Us
WeChat
WhatsApp
Copyright © 2019 Shinjo Valve Co., Ltd.  Powerby:Injnet