Quality That Lasts.

LNG LO2 LN2 Cryogenic Pneumatic Globe Control Valve, Low Temp Range -40℃ ~ -196 °C
Contact:Sales Department
Tel:+86-21 5620 6641
Mobile:+86-13127946805
Email:info@shinjovalve.com
Tags:

ZXPD (DZJHP) LNG LO2 LN2 Cryogenic Pneumatic Globe Control Valve, Low Temp Range -40℃ ~ -196 °C


Nominal diameter: DN20~DN200;
Nominal pressure: PN16, PN40, PN64;
Material: stainless steel (ZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti,etc);
Bonnet type: extended bonnet for -40℃ ~ -196 °C;
Flow characteristic:equal percentage and linear;
Suitable medium:cryogenic medium(such as LNG,LN2,LO2,etc);

The ZXPD cryogenic globe control valve consists of a pneumatic diaphragm actuator and cryogenic single seat globe valve. Cryogenic control valve is appropriate for ultra-cold applications in which the medium temperatures are between -40 ° C and -196 ° C (for example liquid nitrogen, liquid oxygen, etc.).It is different from an ordinary temperature control valve for the reason that cryogenic control valve utilizes a extended bonnet to make sure that the packing works at 70 degrees.Cryogenic Pneumatic Globe Control Valve

The Specification of Single Seat Cryogenic Globe Control Valve:

Product name: straight way single seat cryogenic control valve;
Nominal diameter: DN25~DN300;
Nominal pressure: PN16, PN40, PN64;
Flange standard: GB/T9113, JB/T79.1-94, 79.2-94, etc;
Material: stainless steel (ZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti,etc);
Bonnet type: extended bonnet for -40℃ ~ -196 °C;
Sealing packing: V-type PTFE packing, V-type flexible graphite packing;
Flow characteristic:equal percentage and linear;
Suitable medium:cryogenic medium(such as LNG,LN2,LO2,etc);

Performance Parameter of Single Seat Cryogenic Globe Control Valve:

Nominal diameter(DN)

25

32

40

50

65

80

100

125

150

200

250

300

Seat diameter(dn)

25

32

40

50

65

80

100

125

150

200

250

300

Rated flow  (KV)

single seat

11

17.6

27.5

44

69

110

176

275

440

630

875

1250

Allowable pressure 

difference(MPa)

single seat

3.2

3

2

1.8

1.5

1.4

1

0,7

0.6

0.5

0.3

0.1

Nominal pressure(MPa)

1.6、2.5、4.0、6.4

Rate travel(mm)

16

25

40

60

100

Flow characteristics

equal percentage, linear

Bonnet type

cryogenic type -40~-196℃

Sealing packing

V-type PTFE packing, V-type flexible graphite packing

Plug type

single seat contoured plug

 

The Dimensions of Cryogenic Pneumatic Globe Control Valve:

The Dimensions of Cryogenic Pneumatic Globe Control Valve

DN(mm)

25

32

40

50

65

80

100

125

150

200

250

300

L

PN16/25

184

200

222

254

276

298

352

410

451

550

640

880

PN40

197

200

235

267

292

317

368

425

473

640

760

910

PN64

200

210

251

286

311

337

394

440

508

670

810

950

H

PN16/25

57.5

75

75

85.5

92.5

100

110

142.5

158

170

195

230

PN40

57.5

75

75

82.5

92.5

100

117.5

150

167.5

187.5

205

245

PN64

40

85

85

90

102.5

107.5

125

172.5

195

207.5

230

260

H1

The height-H1 depends on the actual working temperature

H2

298

298

298

298

380

380

380

510

510

510

650

650

A

282

282

282

282

360

360

360

470

470

470

580

580

 Installation instructions of cryogenic globe control valve:

1. It need to be installed vertically around the horizontal pipe. When it's essential to do the installation horizontally or obliquely under special conditions, it ought to generally be supported.

2. The cryogenic globe control valve ought to be installed near to the ground or floor, to be able to maintain and repair. For that situation using the positioner or handwheel mechanism, it's convenient for observation, adjustment and operation.

3. The bypass lines are generally set to change to manual operation once the automatic control system fails or repairs, to ensure that production isn't stopped.

4. Once the handwheel mechanism is installed, the manual operation may also be overlooked once the bypass pipe is overlooked, and it is also employed for the limit opening. Once the me is stopped, the handwheel mechanism should be restored towards the original neutral position to facilitate the standard operation from the automatic control system.

5. When installing, the flow direction from the medium ought to be in conjuction with the direction shown by the valve body.

6. Clean the pipeline and clean the welding slag before installing the cryogenic globe control valve. After installation, fully open, clean the pipeline and try out the tightness of every joint.


About Us

Shinjo Company is a high tech enterprise specialized in producing various industrial valves. Shinjo strive on providing full package of industrial valve solution to client, focus on industrial valve manufacture, development, sales and services.

Contact Us
Tel: +86-21 5620 6641
Fax: +86-21 6915 6667
Mobile: +86-13122293865(WhatsApp)
Skype: maxchi2013
Fllow Us
WeChat
WhatsApp
Copyright © 2019 Shinjo Valve Co., Ltd.  Powerby:Injnet